Welcome to the Fire Pump Company Users' List and Innovations database. Click on a job to the left to view information and innovations.
| CUSTOMER: | Murphy Oil |
| JOB SITE: | Gulf of Mexico |
| DATE: | November 2002 |
| TYPE: | Tension Leg Platform |
| QUAN: | 2 |
| GPM: | 4000 |
| HP: | 739 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | Electric |
| START: | 24 V Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Teppco |
| JOB SITE: | Baytown, TX |
| DATE: | October 2000 |
| TYPE: | UL/FM Pre-Pac Enclosure |
| QUAN: | 3 |
| GPM: | 3500 |
| HP: | 509 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | Electric |
| START: | 24 V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | British Gas Trinidad & Tobago Ltd. |
| JOB SITE: | Trinidad |
| DATE: | May 2000 |
| TYPE: | Fixed Leg Platform |
| QUAN: | 2 |
| GPM: | 2500 |
| HP: | 420 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | Pneumatic |
| START: | Pneumatic |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Shell |
| JOB SITE: | Suriname, South America |
| DATE: | April 2000 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 1500 |
| HP: | 300 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Ercon |
| JOB SITE: | Padre Island State Park |
| DATE: | September 1999 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 750 |
| HP: | 60 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Dixie Chemical |
| JOB SITE: | Pasedena |
| DATE: | October 1998 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 2000 |
| HP: | 235 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Pemex |
| JOB SITE: | Gulf of Mexico |
| DATE: | October 1998 |
| TYPE: | Oil Drilling Platform |
| QUAN: | 1 |
| GPM: | 2500 |
| HP: | 400 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | Manual |
| START: | 460V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Pemex |
| JOB SITE: | Gulf of Mexico |
| DATE: | October 1998 |
| TYPE: | Oil Drilling Platform |
| QUAN: | 1 |
| GPM: | 2500 |
| HP: | 430 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | Manual |
| START: | 24V-HYD |
| Click here to view FPCo INNOVATIONS | |
| CUSTOMER: | Contrina |
| JOB SITE: | Venezuela |
| DATE: | June 1998 |
| TYPE: | United Laboratories of Canada |
| QUAN: | 2 |
| GPM: | 300 |
| HP: | 40 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | Electric |
| START: | 110V-460V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Contrina |
| JOB SITE: | Venezuela |
| DATE: | June 1998 |
| TYPE: | United Laboratories of Canada |
| QUAN: | 2 |
| GPM: | 2500 |
| HP: | 300 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | Electric |
| START: | 10V-2300V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Contrina |
| JOB SITE: | Venezuela |
| DATE: | June 1998 |
| TYPE: | United Laboratories of Canada |
| QUAN: | 3 |
| GPM: | 3000 |
| HP: | 483 |
| PUMP | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | Electric |
| START: | 24V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | British Borneo | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | May 1998 | |||||
| TYPE: | Tension Leg Platform | |||||
| QUAN: | 2 | |||||
| GPM: | 2500 | |||||
| HP: | 430 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Benton Oil |
| JOB SITE: | Venezuela |
| DATE: | April 1998 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 1000 |
| HP: | 156 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Shell Chemical |
| JOB SITE: | Louisiana |
| DATE: | February 1998 |
| TYPE: | SUMP |
| QUAN: | 1 |
| GPM: | 5000 |
| HP: | 175 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Pneumatic |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Shell Chemical |
| JOB SITE: | Louisiana |
| DATE: | February 1998 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 5000 |
| HP: | 800 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Pneumatic |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Mobil |
| JOB SITE: | Beaumont Refinery |
| DATE: | December 1997 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 1500 |
| HP: | 370 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | British Borneo | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | March 1997 | |||||
| TYPE: | Tension Leg Platform | |||||
| QUAN: | 2 | |||||
| GPM: | 2500 | |||||
| HP: | 430 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Marathon | |||||
| JOB SITE: | Sakhalin Islands | |||||
| DATE: | January 1997 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 3500 | |||||
| HP: | 483 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | OPS-Mobil | |||||
| JOB SITE: | W. Africa | |||||
| DATE: | May 1996 | |||||
| TYPE: | Floating Production Storage Operation | |||||
| QUAN: | 1 | |||||
| GPM: | 300 | |||||
| HP: | 420 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Aramco |
| JOB SITE: | Saudi Arabia |
| DATE: | February 1996 |
| TYPE: | United Laboratories/Factory Mill |
| QUAN: | 1 |
| GPM: | 500 |
| HP: | 75 |
| PUMP: | HSC |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Aramco |
| JOB SITE: | Saudi Arabia |
| DATE: | February 1996 |
| TYPE: | United Laboratories/Factory Mill |
| QUAN: | 1 |
| GPM: | 500 |
| HP: | 91 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Safety & Health |
| JOB SITE: | Louisiana |
| DATE: | November 1995 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 500 |
| HP: | 91 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Oryx Process | |||||
| JOB SITE: | Ecuador | |||||
| DATE: | January 1995 | |||||
| TYPE: | National Fire Protection Association | |||||
| QUAN: | 2 | |||||
| GPM: | 2300 | |||||
| HP: | 341 | |||||
| PUMP: | HSC | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | June 1994 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1250 | |||||
| HP: | 230 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Mobil | |||||
| JOB SITE: | Turkey | |||||
| DATE: | May 1994 | |||||
| TYPE: | Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 2500 | |||||
| HP: | 450 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | OPI | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | December 1993 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1200 | |||||
| HP: | 235 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Citgo | |||||
| JOB SITE: | Corpus Christi | |||||
| DATE: | September 1993 | |||||
| TYPE: | National Fire Protection Association | |||||
| QUAN: | 1 | |||||
| GPM: | 750 | |||||
| HP: | 256 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Shell | |||||
| JOB SITE: | New Zealand | |||||
| DATE: | June 1993 | |||||
| TYPE: | Fixed Oil Production Association | |||||
| QUAN: | 1 | |||||
| GPM: | 750 | |||||
| HP: | 256 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Temex |
| JOB SITE: | Mexico |
| DATE: | April 1992 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 2000 |
| HP: | 250 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Unocal |
| JOB SITE: | Thailand |
| DATE: | January 1992 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 1 |
| GPM: | 750 |
| HP: | 150 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | None |
| START: | 460V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | January 1992 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 750 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Iranian Offshore (A) |
| JOB SITE: | Persian Gulf |
| DATE: | August 1991 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 4 |
| GPM: | 3000 |
| HP: | 400 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| Click here to view FPCo INNOVATIONS | |
| CUSTOMER: | Iranian Offshore (B) |
| JOB SITE: | Persian Gulf |
| DATE: | August 1991 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 2 |
| GPM: | 1500 |
| HP: | 230 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| Click here to view FPCo INNOVATIONS | |
| CUSTOMER: | ARCO | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | September 1991 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 280 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Ecopetrol |
| JOB SITE: | Colombia |
| DATE: | July 1991 |
| TYPE: | United Laboratories of Canada |
| QUAN: | 1 |
| GPM: | 2000 |
| HP: | 300 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Ecopetrol |
| JOB SITE: | Colombia |
| DATE: | July 1991 |
| TYPE: | United Laboratories of Canada |
| QUAN: | 1 |
| GPM: | 2000 |
| HP: | 370 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Iranian Offshore |
| JOB SITE: | Persian Gulf |
| DATE: | June 1991 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 1 |
| GPM: | 1500 |
| HP: | 120 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| Click here to view FPCo INNOVATIONS | |
| CUSTOMER: | ARCO | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | February 1991 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 220 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Conoco |
| JOB SITE: | Gabon |
| DATE: | February 1991 |
| TYPE: | National Fire Protection Association |
| QUAN: | 2 |
| GPM: | 300 |
| HP: | 60 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | EKO ABEE | |||||
| JOB SITE: | Greece | |||||
| DATE: | January 1991 | |||||
| TYPE: | Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 235 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Union Texas | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | November 1990 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 3000 | |||||
| HP: | 482 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Shell |
| JOB SITE: | Argentina |
| DATE: | October 1990 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 3200 |
| HP: | 700 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Shell |
| JOB SITE: | Argentina |
| DATE: | October 1990 |
| TYPE: | National Fire Protection Association |
| QUAN: | 3 |
| GPM: | 3200 |
| HP: | 870 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | ARCO | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | September 1990 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 288 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | February 1990 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1250 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | ARCO | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | January 1990 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 3500 | |||||
| HP: | 662 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Seychelles Petroleum |
| JOB SITE: | Seychelle Island |
| DATE: | October 1989 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 3250 |
| HP: | 400 |
| PUMP: | HSC |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Seychelles Petroleum |
| JOB SITE: | Seychelle Islands |
| DATE: | October 1989 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 3250 |
| HP: | 400 |
| PUMP: | HSC |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Petrola Hellas S.A. |
| JOB SITE: | |
| DATE: | June 1989 |
| TYPE: | United Laboratories of Canada |
| QUAN: | 2 |
| GPM: | 2500 |
| HP: | 430 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | B&R | |||||
| JOB SITE: | Persian Gulf | |||||
| DATE: | April 1989 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 500 | |||||
| HP: | 60 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Dixie Pipeline |
| JOB SITE: | Mississippi |
| DATE: | April 1989 |
| TYPE: | National Fire Protection Association |
| QUAN: | 1 |
| GPM: | 1000 |
| HP: | 125 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | December 1988 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 2 | |||||
| GPM: | 750 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal |
| JOB SITE: | Thailand |
| DATE: | December 1988 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 2 |
| GPM: | 750 |
| HP: | 150 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | None |
| START: | 460V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Petrola Hellas S.A. | |||||
| JOB SITE: | Greece | |||||
| DATE: | August 1988 | |||||
| TYPE: | United Laboratories of Canada | |||||
| QUAN: | 6 | |||||
| GPM: | 2500 | |||||
| HP: | 430 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Apache | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | March 1988 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 150 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | November 1987 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 2 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Chevron | |||||
| JOB SITE: | Nigeria | |||||
| DATE: | August 1987 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 250 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Chevron |
| JOB SITE: | Nigeria |
| DATE: | August 1987 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 3 |
| GPM: | 3000 |
| HP: | 600 |
| PUMP: | VTP |
| DRIVE: | Diesel |
| CONTROLLER: | 24V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | PRC | |||||
| JOB SITE: | China Sea | |||||
| DATE: | August 1987 | |||||
| TYPE: | Floating Productin Storage Operation | |||||
| QUAN: | 1 | |||||
| GPM: | 2200 | |||||
| HP: | 420 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Domincan Republic | |||||
| JOB SITE: | Domincan Republic | |||||
| DATE: | July 1987 | |||||
| TYPE: | United Laboratories of Canada | |||||
| QUAN: | 1 | |||||
| GPM: | 2200 | |||||
| HP: | 420 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Shell | |||||
| JOB SITE: | New Zealand | |||||
| DATE: | October 1986 | |||||
| TYPE: | National Fire Protection Association | |||||
| QUAN: | 1 | |||||
| GPM: | 5500 | |||||
| HP: | 1065 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Koch | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | December 1985 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 750 | |||||
| HP: | 100 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Cities Services |
| JOB SITE: | California |
| DATE: | October 1985 |
| TYPE: | Oil Production Terminal |
| QUAN: | 1 |
| GPM: | 3000 |
| HP: | 400 |
| PUMP: | HSC |
| DRIVE: | Electric |
| CONTROLLER: | 110V-460V |
| START: | Electric |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Cities Services | |||||
| JOB SITE: | California | |||||
| DATE: | October 1985 | |||||
| TYPE: | Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 3000 | |||||
| HP: | 400 | |||||
| PUMP: | HSC | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | PG&E | |||||
| JOB SITE: | Utility | |||||
| DATE: | July 1985 | |||||
| TYPE: | United Laboratories of Canada | |||||
| QUAN: | 2 | |||||
| GPM: | 2000 | |||||
| HP: | 250 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | ARCO | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | June 1985 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 3000 | |||||
| HP: | 400 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | May 1985 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 3 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Conoco-Giesum | |||||
| JOB SITE: | Egypt | |||||
| DATE: | May 1985 | |||||
| TYPE: | Floating Production Storage Operation | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 300 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | TX Eastern | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | April 1985 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 200 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Ecopetrol |
| JOB SITE: | Colombia |
| DATE: | February 1985 |
| TYPE: | National Fire Protectin Association |
| QUAN: | 6 |
| GPM: | 500 |
| HP: | 100 |
| PUMP: | HSC |
| DRIVE: | Electric |
| CONTROLLER: | |
| START: | 460V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Enron | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | October 1984 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1400 | |||||
| HP: | 150 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | ||||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Mobil | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | September 1984 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 2 | |||||
| GPM: | 3000 | |||||
| HP: | 500 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | 24V | |||||
| START: | Electric | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Pennzoil | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | July 1984 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1000 | |||||
| HP: | 125 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Sun Oil | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | July 1984 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1000 | |||||
| HP: | 100 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | June 1984 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 4 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Tenneco | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | December 1983 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 2500 | |||||
| HP: | 250 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Tenneco | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | May 1983 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 200 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | December 1985 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 5 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | August 1983 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 210 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal |
| JOB SITE: | Thailand |
| DATE: | June 1983 |
| TYPE: | Fixed Oil Production Platform |
| QUAN: | 2 |
| GPM: | 1250 |
| HP: | 150 |
| PUMP: | VTP |
| DRIVE: | Electric |
| CONTROLLER: | None |
| START: | 460V |
| FPCo INNOVATIONS: | N/A |
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | June 1983 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 8 | |||||
| GPM: | 1250 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | May 1983 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 8 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Unocal | |||||
| JOB SITE: | Thailand | |||||
| DATE: | December 1982 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 4 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic/Methane | |||||
| START: | Methane | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Tenneco | |||||
| JOB SITE: | Louisiana | |||||
| DATE: | December 1982 | |||||
| TYPE: | Cooling Tower Water | |||||
| QUAN: | 2 | |||||
| GPM: | 20000 | |||||
| HP: | 1000 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Conoco | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | June 1982 | |||||
| TYPE: | Fixed Oil Production Platform | |||||
| QUAN: | 1 | |||||
| GPM: | 1000 | |||||
| HP: | 120 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Tenneco | |||||
| JOB SITE: | Louisiana | |||||
| DATE: | March 1982 | |||||
| TYPE: | Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 2000 | |||||
| HP: | 392 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Conoco | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | March 1982 | |||||
| TYPE: | Fixed Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 1100 | |||||
| HP: | 120 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Pennzoil | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | December 1981 | |||||
| TYPE: | Fixed Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 1500 | |||||
| HP: | 160 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||
| CUSTOMER: | Conoco | |||||
| JOB SITE: | Gulf of Mexico | |||||
| DATE: | July 1981 | |||||
| TYPE: | Fixed Oil Production Terminal | |||||
| QUAN: | 1 | |||||
| GPM: | 600 | |||||
| HP: | 90 | |||||
| PUMP: | VTP | |||||
| DRIVE: | Diesel | |||||
| CONTROLLER: | Pneumatic | |||||
| START: | Pneumatic | |||||
| Click here to view FPCo INNOVATIONS | ||||||